CP-PFI.com

PERIODIC FACADE INSPECTION

300+ Facade Inspection Projects across Singapore

Our CP’s rich experience in more than 300+ PFI projects across Singapore brings you unmatched expertise and peace of mind that your statutory requirements will be fulfilled and your building is safe for all. Below is a PFI project and some comments from our CP.

COMMERCIAL · RETAIL

Bukit Panjang Plaza

The building features metal facades with perimeter glazed glass canopy as shelter at the ground floor.

Close-range Inspection

One metal cladding panel was removed to examine the facade system beneath to inspect the anchorage, fasteners and the condition of the backing wall.

Metal cladding is secured to the runner via screws on both lengths of the L-clip.

Typical L-shaped cleat bolted onto wall and runner.

Runner held in place at intervals by L-shaped cleats.

L or Z cleats are used to fasten cladding to runner.

Comments from our CP

Want a similar outcome for your building?

Share your BCA notice with us and we’ll confirm scope and timeline.